Publikácie za rok 2024:
- COCHEROVÁ, Elena** – ZELIESKA, Lukáš – TYŠLER, Milan. Simulation of premature ventricular contractions in patient specific bidomain ventricular model. In Lékař a technika, 2023, vol. 53, no. 2, pp. 14-19. ISSN 0301-5491. Dostupné na: https://doi.org/10.14311/CTJ.2023.2.03 (APVV-19-0531 : Personalized optimisation of cardiac resynchronization therapy in heart failure based on multiple lead ECG measurement. VEGA č. 2/0109/22 : Use of multi-lead ECG measurement and modeling of the electric field of the heart in non-invasive diagnostics and therapy of ventricular arrhythmias and heart failure) Typ: ADMB
- ZELIESKA, Lukáš – COCHEROVÁ, Elena – TYŠLER, Milan. Simulation of ventricular activation in a patient with PVC using computer modeling based on a bidomain reaction-diffusion model. In ELITECH´24 : 26th Conference of Doctoral Students. Zostavovateľ: A. Kozáková; recenzenti: B. Andel, J. Filanová. – Bratislava, SK : Vydavateľstvo Spektrum STU, 2024, 5 p. ISBN 978-80-227-5409-5. (APVV-19-0531 : Personalized optimisation of cardiac resynchronization therapy in heart failure based on multiple lead ECG measurement. VEGA č. 2/0109/22 : Use of multi-lead ECG measurement and modeling of the electric field of the heart in non-invasive diagnostics and therapy of ventricular arrhythmias and heart failure) Typ: AFD
- PŘIBIL, Jiří** – PŘIBILOVÁ, Anna – FROLLO, Ivan. Heart pulse transmission parameters of multi-channel PPG signals for cuffless estimation of arterial blood pressure: Preliminary study. In Electronics, 2024, vol. 13, no. 16, art. no. 3297. (2023: 2.6 – IF, Q2 – JCR, 0.644 – SJR, Q2 – SJR). ISSN 2079-9292. Dostupné na: https://doi.org/10.3390/electronics13163297 Typ: ADCA
- PŘIBIL, Jiří** – PŘIBILOVÁ, Anna – FROLLO, Ivan. Wearable two-channel PPG optical sensor with integrated thermometers for contact measurement of skin temperature. In Engineering Proceedings, 2023, vol. 58, art. no. 108. ISSN 2673-4591. Dostupné na: https://doi.org/10.3390/ecsa-10-16249 Typ: ADMB
- PŘIBIL, Jiří – PŘIBILOVÁ, Anna – FROLLO, Ivan. Stress detection and classification from PPG signals recorded in different conditions – pilot study. In 47th International Conference on Telecommunications and Signal Processing : TSP 2024. – Brno, Czech Republic : Brno University of Technology, 2024, p. 21-25. ISBN 979-8-3503-6559-7. Dostupné na: https://doi.org/10.1109/TSP63128.2024.10605974 (International Conference on Telecommunications and Signal Processing (TSP 2024)) Typ: ADMB
- PŘIBIL, Jiří – PŘIBILOVÁ, Anna – FROLLO, Ivan. Contact measurement of skin temperature using a wearable two-channel PPG optical sensor supplemented by thermometers. In Journal of Electrical Engineering, 2024, vol. 75, no. 2, pp. 113-123. (2023: 1 – IF, Q4 – JCR, 0.221 – SJR, Q3 – SJR). ISSN 1335-3632. Dostupné na: https://doi.org/10.2478/jee-2024-0015 Typ: ADNA
- PŘIBIL, Jiří** – PŘIBILOVÁ, Anna – FROLLO, Ivan. Cuffless estimation of arterial blood pressure based on heart pulse transmission parameters determined from multi-channel PPG signals. In Advances in Signal Processing and Artificial Intelligence : Proceedings of the 6th International Conference on Advances in Signal Processing and Artificial Intelligence (ASPAI‘ 2024). Ed. S.Y. Yurish. – Barcelona, Spain : IFSA Publishing, 2024, p. 8-12. ISBN 978-84-09-60540-8. ISSN 2938-5350. (6th International Conference on Advances in Signal Processing and Artificial Intelligence (ASPAI‘ 2024)) Typ:
- DOGRUSOZ, Y.S.** – BEAR, L. – BERGQUIST, J.A. – RABABAH, A. – GOOD, W. – STOKS, J. – ŠVEHLÍKOVÁ, Jana – VAN DAM, E. – BROOKS, D.H. – MACLEOD, R.S. Evaluation of five methods for the interpolation of bad leads in the solution of the inverse electrocardiography problem. In Physiological Measurement, 2024, vol. 45, art. no. 095012. (2023: 2.3 – IF, Q3 – JCR, 0.544 – SJR, Q2 – SJR). ISSN 0967-3334. Dostupné na: https://doi.org/10.1088/1361-6579/ad74d6 (VEGA č. 2/0109/22 : Use of multi-lead ECG measurement and modeling of the electric field of the heart in non-invasive diagnostics and therapy of ventricular arrhythmias and heart failure. APVV-19-0531 : Personalized optimisation of cardiac resynchronization therapy in heart failure based on multiple lead ECG measurement) Typ: ADCA
- ONDRUŠOVÁ, Beáta** – TIŇO, P. – ŠVEHLÍKOVÁ, Jana. Inverse solution accuracy using 12-lead ECG vs. 9 significant electrodes derived by greedy algorithm. In Computing in Cardiology, 2023, vol. 50, p. non. (2022: 0.212 – SJR). ISSN 2325-8861. Dostupné na: https://doi.org/10.22489/CinC.2023.208 (VEGA č. 2/0109/22 : Use of multi-lead ECG measurement and modeling of the electric field of the heart in non-invasive diagnostics and therapy of ventricular arrhythmias and heart failure. APVV-19-0531 : Personalized optimisation of cardiac resynchronization therapy in heart failure based on multiple lead ECG measurement) Typ: ADMB
- ONDRUŠOVÁ, Beáta – TIŇO, P. – ŠVEHLÍKOVÁ, Jana**. Optimal electrode placements for localizing premature ventricular contractions using a single dipole cardiac source model. In Computers in Biology and Medicine, 2024, vol. 183, art. no. 109264. (2023: 7 – IF, Q1 – JCR, 1.481 – SJR, Q1 – SJR). ISSN 0010-4825. Dostupné na: https://doi.org/10.1016/j.compbiomed.2024.109264 (VEGA č. 2/0109/22 : Use of multi-lead ECG measurement and modeling of the electric field of the heart in non-invasive diagnostics and therapy of ventricular arrhythmias and heart failure) Typ:
- ŠVEHLÍKOVÁ, Jana** – RASOOLZADEH, N. – ONDRUŠOVÁ, Beáta – HLIVAK, P. – DOGRUSOZ, Y.S. Two approaches for inverse PVC localization from clinical ECG data using heart surface potentials. In Computing in Cardiology, 2023, vol. 50, p. non. (2022: 0.212 – SJR). ISSN 2325-8861. Dostupné na: https://doi.org/10.22489/CinC.2023.374 (VEGA č. 2/0109/22 : Use of multi-lead ECG measurement and modeling of the electric field of the heart in non-invasive diagnostics and therapy of ventricular arrhythmias and heart failure) Typ: ADMB