Hydrostatic Optoelectronic Levelling MEasurement System
Hydrostatic digital height gauge HOLMES is designed for automated measurement of height differences between measured points by the hydrostatic levelling method. HOLMES provides precise long term height position measurement of large objects in civil engineering and machine industry, such as reactors in nuclear power plants, high energy particle accelerators etc.
Its function is based on the principle of jointed vessels. The position of common liquid level in the sensors is measured by optoeelectronic method using CCD line image sensors. Numeric value of height differences between sensors bases is computed by original algorithm.
Personal computer is the central unit of this multiprocessor measuring system with distributed intelligence and permits programmable automated measurements e.g. the time dependence of measured points height changes with screen display, storage and printout ability of measurement results.
Our original software may be modified according to user´s requirements.
 
Basic specifications:
Number of measured pointsup to 32
Distance between measured points max. 1000 m
Measuring range± 10 mm
Accuracy of measurements0,1 mm
Resolution0.01 mm
Temperature range (indoor operation)+ 5 to + 40 st. C
Dimensions of sensor l x w x h 455 x 150 x 120 mm
Configuration for reactor simulation
Configuration for reactor simulation
 
PC with HOLMES program
PC with HOLMES program
Old sensor
Old sensor
Old electronics
Old electronics
 
The last hydrolevelling sensor   
The last hydrolevelling sensor
Pendametric sensor   
Pendametric sensor
Covered pendametric sensor
Covered pendametric sensor